Fire Doors

Essential tips to note during fire door installation in Sydney

Fire doors play a substantial role by delaying fire and smoke spreading. By doing this, they support life and the risk control strategies of property damage. However, not all people understand the significant role played by the fire doors in a building.

A fire door can be graded to be more than a regular door leaf. Things like the glass present in the vision panels, the hinges, the seals, the door frame and the ironmongery are categorised to be interdependent as one way of ensuring the door effectiveness. However, the ones who are held responsible for the fire risk strategy of the buildings are not aware effects that are likely to occur as a result of poor selection of the fire doors, poor installation, inspection, and even poor maintenance in the event of a fire.

You can define a fire door as a type of entry that allows the passage of air, persons, and objects and its primary purpose is to resist fire passage or passage of any other gaseous products resulting from combustion. The unique feature with this door is that it’s capable of meeting the intended use within the ends.

This door uses the criteria of relating the integrity level of the fire door regarding fire resistance and smoke spreading. The type of performance needed in this case can only be realised by directing the reference to codes of practice of the building regulation and other necessary standards together with the installation of appropriate fire rated doors in Sydney.

Mostly, the performance criteria of the door can be determined by the door’s prefix FD and then paying attention to the preferred integrity rating, usually expressed in minutes. There are other doors which are specifically meant to restrict spreading of ambient temperature smoke, and this type of entries are identified through the suffix S.

While determining the integrity of the fire doors, the test is conducted when they’re taken as a complete assembly in line to the BS 476/BS EN 1634. If the door passes this test, that is strong assurance that all the assembly components and hardware have passed. This test is an indication that the door becomes reliable only when used together with these specific items. Thus, it’s not right to assume that any component becomes stable with any design or configuration of the fire door.

Whenever purchasing the fire door or installing any components of the fire door, you should keep the above points in mind as a result of change or damage to the building. Therefore, always make the right decision if the whole door set deserves a replacement or not. For the case where you miss one, you may decide to go for the fire door assembly consisting of the individual compatible components.

About the author

Brian Gallagher

View all posts

Leave a Reply